The LF1 is a class 3R autonomous portable laser that features 12 circular 650nm lasers and an 808nm laser at its center for deep and complementary action. It therefore brings together the best of these two fundamental frequencies of rays used for this type of therapy. For more information about this mode of therapy, please refer to the section Introduction of this section regarding therapeutic applications that use the laser. The device operates in stand-alone mode with a rechargeable battery.
Application areas:
- People and animais pain relief, Knee arthritis, Rheumatoid Arthritis, Athletic system injuries, Soft tissue injuries,Relieve muscle and joint pain
- Diminish inflammations, Reduce swelling,Wounds & Ulcers, Osteoarthritis, diabetes, high blood pressure, Acupuncture, Rehabilitation therapy.
Therapeutic theory:
Handhold type pain relief laser equipment is a low level laser therapy (LLLT) device, also known as a soft laser. LLLT is a light source treatment that generates a coherent light of a single wavelength. lt emits no heat, sounds or vibration. The laser's energy is used to penetrate the skin and stimulate the body's natural healing processes, by this way, every cell in the treatment area received the energy activate deep tissue repair , Laser irradiation can diminish inflammation to edema fluid, accelerate the activity of lymphocytes and the body's self-healing system, accelerate the secretion of analgesic substances, reduce the sensitivity of the peripheral nerve, thus for pain treatment.
The association with the distal acupuncture points extend the possibilities of therapies applications with this technology. The user manual (available for download after purchase) shows examples of these applications that do not require a particular knowledge to use them.
The average time of a session is 30 minutes that can be repeated up to 3 times in the day without having any side effect.
Recommendations for use:
- Never look directly at the laser light as this can have serious consequences on your eye.
- It is not recommended to use the laser on pregnant women. As a precautionary principle, people suffering from serious bleeding diseases or having had a cerebral hemorrhage less than 3 months ago should avoid using it because blood thinning is often observed during treatment. If this is the case, the person will have to monitor and adjust their medical treatment according to the use of the device. Apart from treatment on skin having undergone radiotherapy, direct exposure to cancerous areas is not recommended due to ignorance of the possible consequences.
- In some people, there may be an increased heart rate and the need to drink, this is normal because the microcirculation speeds up. We can then reduce the time of use of the device.
Technical characteristics:
Laser wavelength : 650nm ± 20nm & 810nm ± 20nm
A single laser output maximum powerr : de 5mW ± 20% à 150 mW ± 20%
Terminal laser output mode : Continuous
Terminal laser output instabilityr : ≤ ± 10%
Timing range : 10 to 30 minutes
Display mode : Liquid crystal display
Power source : Lithium ion battery with capacity 1800m Ah
Battery voltage : DC 5V
Input power : ≤ 10 VA
Working environment : Temperature 5°C – 40°C, Relative humidity < 80%